The hot tip does the cutting, not the light. Near-infrared diode light is weakly absorbed by soft tissue, so the laser heats a glass tip to 500–900 °C; the hot, charred tip then cuts by contact, much as electrocautery does.[1,2] A CO2 laser operates differently: its 10,600 nm beam is absorbed by the tissue itself and vaporizes it at only 100 °C.[3]
Key takeaways
- A cutting diode behaves like electrocautery in your hand: the light heats a charred glass tip, and the hot glass tip does the cutting.[1,2,4]
- How much heat reaches the tissue depends on the char’s state and your hand speed, so the same tip can cut cleanly early in a case but drag later.[1,2]
- In a small randomized pilot study, the heat-damaged margin was much wider with a diode than with a CO2 laser.
- Diode tips are disposable, so every case carries a tip cost; a CO2 laser cuts with the beam and has no tip to replace.[3,5,6]
- Clinicians who switched from diodes to CO2 lasers describe diodes as contact heat tools.[7,8]
Is a hot glass tip diode cutting tissue with laser light?
No. Diode light at 800–1,100 nm is extremely weakly absorbed by soft tissue and cannot ablate it. Instead, the light heats a charred glass tip to 500–900 °C, which then heats the tissue by conduction.[1] An independent diode-surgery paper puts standard hot tips at several hundred degrees and gives 500–900 °C as the optimal range for a newer temperature-controlled tip.[2]
Robert Levine, DDS, said: “Cutting with a diode laser requires activating the tip.” Later in the same interview: “In essence, they function as … micro-electro-surgery units.”[4] Richard Winter, DDS, who uses a LightScalpel laser, is blunter: “Dental diodes do not cut the tissue with photons, but with hot charred glass!”[9]
In a 2019 lecture, Dr. Levine said that for babies under three months, who usually receive only a topical anesthetic, he generally uses a CO2 laser: “I’m not that comfortable taking a 400-degree hot tip and popping it on a baby without the anesthetic.”[10]
How does the glass tip get hot enough to cut?
The tip has to be “initiated,” which means coated with a light-absorbing char. Burnt ink and cork are listed as methods for making the char.[1]
The char wears away as the glass tip is dragged through the soft tissue, so the tip changes as you work. Degraded char lowers tip temperature and allows the glass edges to tear tissue, thereby increasing the risk of bleeding.[1] Martin Kaplan, DMD, adds that a worn char allows more light to pass through the “partially transmitting” tip, which increases the risk of near-infrared necrosis beneath the surface.[11]
Pre-initiated tips arrive with the char already applied, so the operator skips that step, and the tip still cuts by heating a char layer. They are single-use, so their cost recurs with every use. As of September 2026, one retailer lists 25-packs of pre-initiated surgical diode tips at $279.99, or $11.20 per tip.[5] Another lists a 25-pack of 400 µm diode tips at $235.99, or $9.44 per tip.[6] Jennifer White, DDS, a general dentist who owns both a diode and a CO2 laser, was asked in a webinar about lower-cost lasers for dentists who only plan to do frenectomies. Her answer: “Are diodes cheaper? Yes. Would I do [a frenectomy]? No.”[12]
How is CO2 laser cutting different?
The CO2 laser’s beam does the cutting, and no heated glass tip is involved. At 10,600 nm, energy is absorbed in the outer layer of soft tissue, thereby removing it photothermally and coagulating a thin margin. The coagulation depth is about 50 µm, close to the 20–40 µm diameter of oral soft-tissue capillaries.[3]
LightScalpel’s founder and a co-author, Peter Vitruk, PhD, MInstP, says that the coagulation depth closely matching the diameter of oral soft-tissue capillaries is why CO2 coagulation reaches just deep enough into a severed vessel to stop the bleeding.[3] Robert Levine, DDS, draws the same distinction: “Unlike diode lasers, CO2 lasers utilize ablation and vaporization to cut out-of-contact instead of being placed in direct contact with the tissue that requires treatment.”[4] The beam is invisible infrared light, so the surgeon watches the tissue rather than the beam. Figure 1 puts the two side by side.

How far does heat spread into the surrounding tissue with a diode hot glass tip?
It varies with tip char and technique, and it can exceed what hemostasis requires. Hot-tip coagulation ranges from sub-millimeter to multi-millimeter depths, depending on the degree of charring of the tip.[3] In fixed-power diode lasers, a snag or drag can cause collateral damage beyond 1 mm,[2] whereas hemostasis requires only 50–100 µm in most soft-tissue types.[3,13]
A halo of infrared light around a partially initiated tip greatly deepens necrosis; one way to limit it is to minimize contact time.[1]
Piya Gandhi, DDS, MSD, a pediatric dentist in Houston, says she does not like diode lasers for frenectomy in any age group, “but specifically for infants because of the post-op heat damage that it causes.” She grants that the cautery keeps the bleeding risk “almost none,” but says “that cauterization really does cause a lot more scar tissue risk and granulation.” She also notes that a hygienist can use a diode for other in-office work.[7]
What does a revision after a diode frenectomy look like?
Published evidence is limited to case reports. One describes a 51-year-old woman whose lingual frenum was released two years earlier with a diode hot tip. She came back with recurrent tightness and bunching scar tissue, along with jaw pain, tongue biting, and moderate sleep apnea. A revision with a LightScalpel SuperPulse CO2 laser followed.[13]
Jaw opening increased from 36 mm before surgery to 46 mm immediately after the revision surgery and to 52 mm at 4 weeks. The report describes a bloodless release under topical anesthetic and a scar-free tongue at four weeks.[13] A related paper notes that a CO2 laser tongue-tie release usually needs no sutures and leaves no scar, which matters for the tongue exercises that follow.[14] It is one patient without histology, and she also had myofunctional therapy after the release, so the case cannot show how much of the gain was attributable to the laser itself.
Does it matter whether a diode is called a laser?
Yes, because a hot glass-tip cautery device is used differently from a laser. The published argument is that without knowing that a cutting diode is a hot glass-tip cautery device, it is hard to use one properly, and that such procedures should not be called laser frenectomies.[1]
Gordon J. Christensen, DDS, MSD, PhD, of Clinicians Report makes the point in plain terms:
“…diode laser isn’t a laser. Well, it emits light. But does it emit light? No, you have to put some black thing on the end of it which does what? Stops the light. Light turns to what then? Heat.” Gordon J. Christensen, DDS, MSD, PhD, Clinicians Report (video: Watch on YouTube, 39:30)[15]
Dr. Richard Winter comes to the same conclusion, calling diodes “thermal contact ablation devices and not laser wavelength-dependent precise cutting instruments”.[9]
Dr. Kaplan, who used a diode years ago before moving to a CO2 laser, said in a 2025 webinar: “A diode isn’t really a … laser; it’s actually like a contact electrosurgical instrument.”[8]
What should you ask a manufacturer who won’t explain how the diode glass tip works?
Ask for the wavelength and whether the beam or a heated tip cuts the tissue. Then work through the five factors listed for hot glass tip devices: initiation, char wear, biocompatibility, fracture, and contact time.[11] Here are seven questions worth putting to any manufacturer.
- Does the beam or a heated tip cut the tissue?
- How is the tip initiated, and how is the initiation material (char) biocompatible? What is known about the biocompatibility and sterility of the char (burned ink or cork, for example) and of the glass and chemical coating cladding at 500–900 °C?
- What is the likelihood that the heated glass tip will break during the procedure and fall into the patient’s mouth?
- What limits prevent thermal-gradient fracture of the tip, and what is known about the biocompatibility of fragments?
- How is char degradation detected during a procedure, given that worn char lowers tip temperature and can increase tearing and necrosis below the surface?
- How much do surgical results, pain, and healing depend on operator skill?
- How do hand speed and tip contact time change coagulation depth?
To compare surgical CO2 laser technology with diode in detail, read the LightScalpel technology comparison. To see a 10,600 nm CO2 laser in action, contact LightScalpel to arrange a demonstration.
References
- Vitruk P. Hot glass tip diode frenectomies ARE NOT laser frenectomies. Dent Sleep Pract. Summer 2019:48–50.
- Romanos GE. Diode laser soft-tissue surgery: advancements aimed at consistent cutting, improved clinical outcomes. Compend Contin Educ Dent. 2013 Nov–Dec;34(10):752–757; quiz 758. PMID 24571504.
- Vitruk P, Levine R. Hemostasis and coagulation with ablative soft-tissue dental lasers and hot-tip devices. Inside Dentistry. 2016;12(8):37–42.
- Levine R. The state of the art of lasers [interview]. Inside Dentistry. 2017 Nov;13(11):76. https://insidedentistry.net/2017/11/the-state-of-the-art-of-lasers
- AMD Lasers. Picasso disposable laser tips, pre-initiated surgical tips, 25-pack. amdlasers.com/products/disposable-multi-tips. Accessed September 18, 2026.
- Sky Dental Supply. Diode laser tip (4 mm, 400 µm), 25/pkg. skydentalsupply.com/diode-laser-tips-25.htm. Accessed September 18, 2026.
- Gandhi P. The Function First Model: the key to building a successful TOTS practice [webinar recording]. American Laser Study Club. August 8, 2023. americanlaserstudyclub.org/webinar/webinar-recording-the-function-first-model-the-key-to-building-a-successful-tots-practice/. Quotes at 53:01 and 53:29.
- Kaplan M. Getting to the next level: how to better handle frenum release challenges [webinar recording]. American Laser Study Club. November 5, 2025. americanlaserstudyclub.org/webinars/. Quote at 1:02:50.
- Winter RB. Practical laser applications in general practice. Dentistry Today. 2017 Jun:78–83. https://www.lightscalpel.com/wp-content/uploads/2017/06/winter-Practical-Laser-Applications-in-General-Practice-v2.pdf
- Levine R. Laser use in the academic environment: what we are teaching our pre-doctoral students [symposium lecture]. American Laser Study Club Symposium; 2019. Quote at 5:06.
- American Laser Study Club. Soft-tissue cutting with hot glass tip diodes. December 6, 2017. americanlaserstudyclub.org/soft-tissue-lasers/soft-tissue-cutting-hot-glass-tip-diode-laser/ (includes statements by Levine, Winter, and Kaplan).
- White J. Maximizing the use of lasers in a general dentist office [webinar recording]. American Laser Study Club. September 12, 2023. americanlaserstudyclub.org/webinars/. Quote at 30:28.
- Riek C, Vitruk P. Incision and coagulation/hemostasis depth control during a CO2 laser lingual frenectomy. Dent Sleep Pract. Spring 2018:32–38.
- Fabbie P, Kundel L, Vitruk P. Tongue-tie functional release. Dent Sleep Pract. Winter 2016:40–45.
- Christensen GJ. 1009 No Bull with Gordon J. Christensen, DDS, MSD, PhD: Dentistry Uncensored with Howard Farran . Clinicians Report. May 2018. youtube.com/watch?v=te-mmhmKf0A. Quote at 39:30.